OceanOpticsSpectrometer>> Fluorescence Spectrometer>>USB2000-FLG Gated Fluorescence Spectrometer  

The USB2000-FLG is a high-sensitivity spectrofluorometer that is preconfigured for fluorescence applications from 380-1050 nm.

We utilize a proprietary thin film technology and a time-gated spectrometer to provide a spectrofluorometer that is 20 percent more sensitive than the standard USB2000 Spectrometer. The USB2000-FLG is available for.

Features

  • AgPlus Mirrors increase system sensitivity by 20% over standard USB2000

  • Gated mode eliminates scattered excitation light to enhance phosphorescence measurements

  • Full 380-1050 nm range analysis

AgPlus Mirrors

We replaced our standard mirrors with our proprietary AgPlus Ag-coated mirrors to increase reflectance, which in turn increases the sensitivity of the spectrometer by 10-35% percent. Not only do these mirrors create a more sensitive spectrometer, they also absorb nearly all UV light, virtually eliminating the excitation source's spectra from interfering with the sample spectra. Pairs of AgPlus mirrors (item SAG+UPG) are available for $250.

Gated Phosphorescence Mode

The USB2000-FLG is preloaded with variable-delay gating microcode, which allows you to select a delay (from 5-500 microseconds) between the light turning on and the start of the spectrometer's integration time, or the amount of time the detector "sees" the sample. In this mode, the spectrometer only detects the sample light when the source is off. However, in order to use the gated phosphorescence mode, your fluorophore must have a long fluorescence lifetime. Those working with lanthanides and phosphorescent materials will find the gated phosphorescence mode particularly useful.

L2 Detector Collection Lens

The USB2000-FLG's detector window is fitted with an L2 Detector Collection Lens. This cylindrical lens increases the spectrometer's light-collection efficiency and reduces stray light. The L2 is especially useful with a large-diameter fiber for low light-level applications.

Accessory Filters

The USB2000-FLG can be used with our LVF-series Linear Variable Filters to construct systems with excellent separation of excitation and fluorescence energy. Use our LVF-L Linear Variable Low-pass Filter to fine tune your excitation source for maximum signal with minimum overlap; and/or use our LVF-H Linear Variable High-pass Filter on the detection side. Inline holders and cuvette fixtures make deployment of these filters easy.

Applications

The USB2000-FLG can detect fluorophores in liquids and powders, and from surfaces. We use the USB2000-FLG in our EDS2000 System to detect anthrax. The USB2000-FLG is field-portable -- use it to detect fluorescence in coral, fruit and other flora and fauna.

USB2000-FLG Sample Spectra



This graph shows the fluorescence of nanomolar (nM) concentrations of fluorescein. We made the measurements with a USB2000-FLG, an LS-450 Blue LED Light Source, a CUV-ALL and an LVF-L Low-pass Filter to limit the blue LED to < 475 nm. We set the integration time to 100 msec. Longer integration times allow the system to detect fluoroscein in the picomolar range.

Specifications

Spectrometer:

USB2000-FLG; Master spectrometer channel only

Grating:

Grating #3 -- 600 lines per millimeter, blazed at 500 nm

Detector:

2048-element linear silicon CCD array; L2 Collection Lens

Wavelength range:

380-1050 nm

Entrance aperture:

200 µm wide slit

AgPlus Mirrors:

Provide reflectivity >95% over the visible and NIR wavelength range and over a wide range of angles of incidence

Integration time:

5 milliseconds in gated mode, 5 msec-20 seconds in normal mode

Data transfer rate:

  • Full scans (2048 wavelengths) into memory every 13 milliseconds

  • Time acquisition approximately every 25 milliseconds

Optical resolution:

~10.0 nm FWHM

Stray light:

~0.05% at 600 nm, <0.10% at 435 nm

Power consumption:

90 mA @ 5 VDC

Dimensions:

89.1 mm x 63.3 mm x 34.4 mm

Weight:

190 g

Computer interface:

Universal Serial Bus (RS-232 available on side connector)

Computer requirements*:

  • IBM-compatible PC with Pentium or better microprocessor

  • 32 MB RAM (16 MB)

  • Windows 98/Me/2000/XP, Mac OS X and Linux when using the USB interface on desktop or notebook PCs.

  • Any 32-bit Windows operating system when using the serial port on desktop or notebook PCs. Windows 

  • CE 2.11 and above when using the serial port on handheld PCs.

Operating software:

SpectraSuite (for an additional $199)

Fiber optic connector:

SMA 905 to single-strand optical fiber

 
版權所有 2007 廣州標旗光電科技發展股份有限公司 www.bhscgy.com
地址:廣州市黃埔區彩頻路7號701-1房
電話:(020)38319602 38319620 傳真:(020)38319595 ICP備案:粵ICP備2024341827號 粵公網安備44011202002999
主站蜘蛛池模板: 国产欧美综合一区二区三区 | 九色av| 老妇激情毛片免费 | 国产精品久久久久久久9999 | 99re国产 | 狠狠爱天天干 | 亚洲精品成人网 | 亚洲怡红院在线观看 | 99国产精品久久久久久久 | 日韩福利电影 | 精品国产乱码久久久久久1区2区 | 少妇一区二区三区 | 日韩精品99 | 国产黄色大片免费看 | 日本久久视频 | 国产视频第一区 | 久久久久久久久99精品 | 日本高清视频在线播放 | 高清一区二区 | 26uuu成人免费毛片 | 久久最新 | 蜜月aⅴ免费一区二区三区 99re在线视频 | 国产精品99久久免费观看 | 国产成人精品高清久久 | 国产精品国产精品国产专区不卡 | 国产精品高潮呻吟 | 午夜av在线 | 午夜久久久 | 羞羞视频免费观看 | 久色视频在线观看 | 国产91在线播放精品91 | 嫩草影院黄色 | 国产精品一区人伦免视频播放 | 精品中文字幕一区二区三区 | 国产一区免费在线观看 | 91在线视频免费观看 | 日韩精品一区二区三区在线观看 | 国产亚洲一区二区三区在线观看 | 最新午夜 | 人人看人人草 | 国产精品美女久久久久aⅴ国产馆 |