Contact an Biaoqi Applications Scientist

 
Product List
QSpec
OceanOpticsSpectrometer
Light Sources
New Product
* PL-3000 Photoluminescence Spectrometer
* GLIS-3000 GEM Luminous Imaging 
* bluLoop Multi-LED Light Source
* HL-2000 Tungsten Halogen Light 
* LS-1 Tungsten Halogen Light So
* DH-2000 Deuterium Tungsten Halogen&
* Balanced Deuterium Tungsten Halogen
* Miniature Deuterium Tungsten Haloge
* D-2000 Deuterium Light Sources
* High-powered Continuous-wave Xenon 
 
Product

OceanOpticsSpectrometer>> Oxygen Sensors System>>FOSPOR Sensor Formulation  

FOSPOR Sensor Formulation


The FOSPOR coating is applied to the distal end of the fiber and has a fluorescence-based Pt-porphyrin indicator. The sensor uses fluorescence quenching of the porphyrin to measure the partial pressure of dissolved or gaseous oxygen. The FOSPOR coating can be applied to substrates other than fibers and probes and used for applications such as through-packaging measurements in the food and pharmaceutical industries. *Please contact an Applications Scientist before specifying FOSPOR or other coatings.

Choosing a Probe
Once you choose the best Sensor Coating Formulation for your application, you need to select the fiber optic probe onto which the sensor coating is applied. For a list of fiber optic probes, click here.

FOSPOR Coating Specifications

Specification  
Principle Photoluminescence-quenching using Pt compound. Measures O2 partial pressure.
Sensor mechanism Phase shift due to change in partial pressure of O2
Applications Low O2 (0–5%), vacuum systems packaging, benign environment
Time-constant (µsec) dynamic range Air: 10.00; N2: 50.00; Low: 3.00, High: 70.00
Accuracy: (0–20% O2, 0–50ºC) <5% of reading (using polynomial fit to multipoint calibration)
Response time of probe with no overcoat <30-60 seconds in gas, 60-90 seconds in liquid
Response time of dissolved oxygen in liquid (with overcoat) 30-45 seconds
Response time of probe with Overcoat of Oxygen Gas (at 1 atmosphere) 60-120 seconds
Dynamic range of Dissolved Oxygen in liquid 0–4.1 ppm; 0–75 mm Hg partial pressure
Dynamic range of Oxygen Gas (at 1 atmosphere) 0–<10% (mole percent); 0–760 mm Hg partial pressure
Stability Dissolved Oxygen in liquid Drift < 0.00008 ppm O2 per hour at low dissolved oxygen; Drift ~ 0.006 ppm O2 per hour in air-saturated water
Stability Oxygen Gas (at 1 atmosphere) Drift ~ 0.0002% O2 drift per hour at low O2; Drift ~ 0.015% O2 per hour air
Resolution of Dissolved Oxygen in liquid 0.002 ppm at room temperature
Resolution of Oxygen Gas (at 1 atmosphere) 0.005% at room temperature
Lowest detectable limit of Dissolved Oxygen in liquid 0.002 ppm at room temperature
Lowest detectable limit of oxygen gas (at 1 atmosphere) 0.005% (0.04 mm Hg)
Overcoat available Yes
Temperature range 0ºC to +60ºC
Temperature Temperature sensor and software-supported compensation
Temperature recalibration Only when probe is replaced/refurbished
Probe lifetime Reconditioning recommended once per year
pH operating range 1-10 pH
 
版權所有 2007 廣州標旗光電科技發展股份有限公司 www.bhscgy.com
地址:廣州市黃埔區彩頻路7號701-1房
電話:(020)38319602 38319620 傳真:(020)38319595 ICP備案:粵ICP備2024341827號 粵公網安備44011202002999
主站蜘蛛池模板: 国产精品二区三区在线观看 | 精品国产一区探花在线观看 | 欧美日本三级 | 99免费视频 | 一级黄色录像在线观看 | 成人久久久精品国产乱码一区二区 | 日本精品视频在线观看 | 亚洲一区二区三区四区在线观看 | 色综合久久久 | 国外成人在线视频网站 | 亚洲成人看片 | 欧美一区二区另类 | 午夜国产精品视频 | 91在线精品一区二区 | 成人在线观看免费视频 | 亚洲精品久久久久国产 | 国产成人精品免费视频大全最热 | 成人福利网站 | 久久久久久91| 国产免费一区二区三区 | 天天干天天去 | 欧美在线a | 国产精品视频 | 亚洲一区二区三区高清 | 国产一区二区自拍 | 国产精品乱码一区二区三区 | 九九免费精品视频 | 婷婷久久综合 | 国产视频福利一区 | 亚洲精品乱码 | 国产精品免费看 | 国产99久久久精品视频 | 欧美videosex性欧美黑吊 | 亚洲综合福利视频 | 日韩午夜一级片 | 91国产精品 | 日本精品一区 | 国产精品一区二区av | 羞羞视频在线观免费观看 | 在线观看一区 | 欧洲精品一区 |