OceanOpticsSpectrometer>> Oxygen Sensors System>>FOSPOR Sensor Formulation  

FOSPOR Sensor Formulation


The FOSPOR coating is applied to the distal end of the fiber and has a fluorescence-based Pt-porphyrin indicator. The sensor uses fluorescence quenching of the porphyrin to measure the partial pressure of dissolved or gaseous oxygen. The FOSPOR coating can be applied to substrates other than fibers and probes and used for applications such as through-packaging measurements in the food and pharmaceutical industries. *Please contact an Applications Scientist before specifying FOSPOR or other coatings.

Choosing a Probe
Once you choose the best Sensor Coating Formulation for your application, you need to select the fiber optic probe onto which the sensor coating is applied. For a list of fiber optic probes, click here.

FOSPOR Coating Specifications

Specification  
Principle Photoluminescence-quenching using Pt compound. Measures O2 partial pressure.
Sensor mechanism Phase shift due to change in partial pressure of O2
Applications Low O2 (0–5%), vacuum systems packaging, benign environment
Time-constant (µsec) dynamic range Air: 10.00; N2: 50.00; Low: 3.00, High: 70.00
Accuracy: (0–20% O2, 0–50ºC) <5% of reading (using polynomial fit to multipoint calibration)
Response time of probe with no overcoat <30-60 seconds in gas, 60-90 seconds in liquid
Response time of dissolved oxygen in liquid (with overcoat) 30-45 seconds
Response time of probe with Overcoat of Oxygen Gas (at 1 atmosphere) 60-120 seconds
Dynamic range of Dissolved Oxygen in liquid 0–4.1 ppm; 0–75 mm Hg partial pressure
Dynamic range of Oxygen Gas (at 1 atmosphere) 0–<10% (mole percent); 0–760 mm Hg partial pressure
Stability Dissolved Oxygen in liquid Drift < 0.00008 ppm O2 per hour at low dissolved oxygen; Drift ~ 0.006 ppm O2 per hour in air-saturated water
Stability Oxygen Gas (at 1 atmosphere) Drift ~ 0.0002% O2 drift per hour at low O2; Drift ~ 0.015% O2 per hour air
Resolution of Dissolved Oxygen in liquid 0.002 ppm at room temperature
Resolution of Oxygen Gas (at 1 atmosphere) 0.005% at room temperature
Lowest detectable limit of Dissolved Oxygen in liquid 0.002 ppm at room temperature
Lowest detectable limit of oxygen gas (at 1 atmosphere) 0.005% (0.04 mm Hg)
Overcoat available Yes
Temperature range 0ºC to +60ºC
Temperature Temperature sensor and software-supported compensation
Temperature recalibration Only when probe is replaced/refurbished
Probe lifetime Reconditioning recommended once per year
pH operating range 1-10 pH
 
版權所有 2007 廣州標旗光電科技發展股份有限公司 www.bhscgy.com
地址:廣州市黃埔區彩頻路7號701-1房
電話:(020)38319602 38319620 傳真:(020)38319595 ICP備案:粵ICP備2024341827號 粵公網安備44011202002999
主站蜘蛛池模板: 国产精品久久九九 | 亚洲伦理在线 | 国产真实精品久久二三区 | 一色屋精品久久久久久久久久 | 草草成人 | 成人免费高清 | 国产美女中出 | 亚洲欧美日韩精品久久奇米色影视 | 久久久午夜爽爽一区二区三区三州 | 免费在线观看国产 | 国产在线一区二区 | 日韩在线中文字幕视频 | 二区欧美 | 91午夜伦伦电影理论片 | 在线观看国精产品二区1819 | 成人性视频在线 | 国产日韩欧美视频 | 黄色三级网站 | 黄色一级大片在线免费看产 | 亚洲 中文 欧美 日韩 在线观看 | 激情欧美一区二区三区中文字幕 | 日韩欧美a级v片免费播放 | 婷色综合 | 一区在线视频 | 欧美综合区| 在线免费国产 | 亚色在线| 天天综合网91 | 中文字幕视频在线 | 精品国产乱码久久久久久久软件 | 天天操操 | 在线免费黄色 | 一级黄视频 | 一区二区三区自拍 | 在线视频一区二区三区 | 色婷婷综合久久久久中文一区二区 | 中文字幕久久精品 | 午夜视频在线观看网站 | 成人免毛片 | 在线观看国精产品二区1819 | 亚洲美乳中文字幕 |