Product

Light Sources>> Radiometric Calibration Source>>LS-1-CAL Radiometric Standard (300-1050 nm)  

Radiometric Calibration Standards

The LS-1-CAL and HL-2000-CAL Calibrated Tungsten Halogen Light Sources calibrate the absolute spectral response of a radiometric system. With one of these NIST-traceable light sources and our software, you can determine known absolute intensity values at wavelengths from 300-1050 nm.

  • NIST-traceable Calibration from 300-1050 nm. Provides absolute spectral intensity in µW/cm2/nm at the fiber port

  • Sources can be calibrated specifically for a bare fiber, a fiber plus cosine corrector, or an integrating sphere

  • Calibration Certificate. Calibration data is provided in paper and electronic formats.

Calibrated for Use with Fiber and Cosine Corrector

The LS-1-CAL and HL-2000-CAL are specifically designed for calibrating the absolute spectral response of a complete system consisting of a spectrometer and an optical fiber and/or a CC-3-UV Cosine Corrector. The calibration data for both the LS-1-CAL and the HL-2000-CAL includes absolute intensities for wavelengths between 300–1050 nm.

Calibrated for Use with Integrating Sphere

The LS-1-CAL-INT is designed for calibrating the absolute spectral response of your system when using the FOIS-1 Fiber Optic Integrating Sphere as your sampling optic. The LS-1-CAL-INT comes with a PTFE diffuser plug that fits snugly into the sample port of the FOIS-1 Integrating Sphere to measure absolute spectral intensities of LEDs and other emission sources. The HL-2000-CAL-ISP is designed for calibrating the absolute spectral response of your system when using the ISP-50-8-I Integrating Sphere as your sampling optic.

Included with the Lamps

Each one of these radiometric sources comes with a regulated 12 VDC power supply. Also included is a calibration certificate and a CD with data files for use with our software.

Other Calibration Services

The LS-1-CAL provides 50 hours of operation before recalibration is necessary. We recalibrate these lamps in-house. (For more information on LS-1-RECAL, contact an Applications Scientist.) For those with spectroradiometric systems working below the 300-1050 nm range of the LS-1-CAL and HL-2000-CAL, see our DH-2000-CAL.

Pricing

Item Code Description Price
LS-1-CAL Radiometric Calibration Standard, 300-1050 nm
LS-1-CAL-INT Radiometric Calibration Standard, 300-1050 nm
LS-1-CAL-EXT Upgrade for extended range.
LS-1-RECAL Radiometric Re-calibration Service for the LS-1-CAL and LS-1-CAL-INT
HL-2000-CAL Radiometric Calibration Standard, 300-1050 nm
HL-2000-CAL-ISP Radiometric Calibration Standard, 300-1050 nm
HL-2000-RECAL Radiometric Re-calibration Service for the HL-2000-CAL and HL-2000-CAL-ISP

LS-1-CAL Spectral Output


Spectral output of the LS-1-CAL using a bare SMA-terminated fiber

Spectral output of the LS-1-CAL using a CC3 cosine corrector


Spectral output of the LS-1-CAL-INT when connected to a FOIS-1 integrating sphere

LS-1-CAL and HL-2000-CAL Specifications

Spectral range (calibrated): 300-1050 nm (calibrated)
Power consumption:

800 mA @ 12 VDC

Power output: 6.5 watts
Bulb life:

900 hours (recommend recalibration after 50 hours of use)

Recalibration: Required after ~50 hours of operation
Bulb color temperature:

3100 K

Output regulation: 0.2% voltage
Time to stabilized output: ~30 minutes
Connector: SMA 905 for fiber; 6.35-mm barrel for cosine corrector; PTFE plug for integrating sphere
 
版權所有 2007 廣州標旗光電科技發展股份有限公司 www.bhscgy.com
地址:廣州市黃埔區彩頻路7號701-1房
電話:(020)38319602 38319620 傳真:(020)38319595 ICP備案:粵ICP備2024341827號 粵公網安備44011202002999
主站蜘蛛池模板: 亚洲欧洲精品一区二区 | 国产精品美女久久久 | 亚洲a在线观看 | 这里只有精品视频 | 欧美日韩精品在线一区 | 久久国产精品免费一区二区三区 | 日韩在线短视频 | 久久久成 | 美女91| 欧美福利电影在线观看 | 中文字幕亚洲一区二区va在线 | 久久久精 | 国产日韩一区二区 | 国产高清精 | jizz欧美大片 | 91亚洲精品乱码久久久久久蜜桃 | 欧美久久久久久 | 成人av一区二区三区 | 日韩久草 | 久久久久综合狠狠综合日本高清 | 亚洲综合一二区 | 亚洲精品一区二区三区 | 欧美一级黄带 | 国产69精品99久久久久久宅男 | 成人免费淫片aa视频免费 | 欧美精品一区在线 | 国产91网 | 国产精品久久久久9999 | 日韩在线1 | 成人影院欧美黄色 | 欧美日韩精品久久 | 亚洲欧洲精品成人久久奇米网 | 亚洲精品一区二区在线 | 国产精品二区三区 | av网站网址 | 亚洲欧美一区二区三区在线 | 精品国产乱码久久久久久久软件 | 一区二区在线电影 | 天天综合网久久综合网 | 国产精品久久国产愉拍 | 精品免费国产一区二区三区 |